About this Program

Capture a better health outlook through diagnostic imaging

16 CE, Mammography Registry Review 4-part Webinar Series follows the ARRT content specifications as outlined in the most current Mammography Certification Handbook. This webinar series is appropriate for mammographers wanting mammography board exam prep for the ARRT Mammography registry or to enhance current knowledge in mammography and breast imaging.

How hard is the mammography registry?

Earning your ARRT certification and registration for mammography is challenging, but it is very possible! MTMI will provide you the training that you need, both didactic and clinical placement (if needed), to get you on your way to success! The mammo registry review webinar series offers a study guide for your certification exam covering breast imaging, pathology, anatomy, and more. MTMI students have a 98% mammography registry pass rate!

A certificate of attendance, documenting 4-credit hours will be provided for each individual upon completion of each 3.5-hour webinar session. Completing all 4 sessions of this series will provide the 16 hours of structured education related to the content specifications outlined by the ARRT, required for certification and registration.

Session 4 meets 4 hours of the 8-hour MQSA requirement for initial training in digital mammography as it pertains to physicists and radiologic technologists.

A printable download will be available to each registrant prior to each session of the Mammography Registry Review webinar. This will allow you to follow along with the presentation and make notes for your study guide as you feel necessary.

Tuition listed is per session.

 

NEW! Mammography Registry Review On-Demands Now Available:

Mammography Registry Review Series: Part 1 

Mammography Registry Review Series: Part 2

Mammography Registry Review Series: Part 3

Mammography Registry Review Series: Part 4

 

Educational Objectives

At the completion of this Mammography Registry Review webinar series, participants will:

  • Understand the differences between regulatory bodies, such as MQSA, ACR and the ARRT.
  • Obtain knowledge to help prepare for the ARRT Mammography exam.
  • Gain knowledge on the various treatment options for various types of breast diseases.
  • Review patient care techniques including documentation of patient history, informed consent and more.

Schedule

What this course will cover

Session 1

6:30pm Eastern
5:30pm Central
4:30pm Mountain
3:30pm Pacific

What's my timezone?

Regulations & Patient Care

Accreditation and Certification

  • Purpose, Process, & Frequency
  • Accrediting Agencies
    • MQSA
      • Voluntary quality control
      • Regulations
      • Personnel requirements, record keeping
      • Medical outcome audit
      • EQUIP
        • Clinical image quality, quality oversight
  • ACR/FDA
    • 3-year accreditation information
    • FDA role in yearly evaluation of clinics

Patient Interactions & Management

  • Patient Communication
    • Pre-exam, explanation of exam, post-exam and patient education
  • Patient Assessment
    • Risk factors for breast cancer
    • Incidence of breast cancer
    • Signs & symptoms
    • Documentation
    • Necessity of prior images
    • Treatment Options
      • Surgical
      • Non-surgical
      • Reconstruction

Evaluation of Image Quality

  • Positioning
  • Compression
  • Exposure
  • Contrast
  • Sharpness
  • Noise
  • Artifacts
  • Collimation
  • Motion

 

Session 2

6:30pm Eastern
5:30pm Central
4:30pm Mountain
3:30pm Pacific
What's my timezone?

Anatomy & Pathology

Localization Terminology

  • Clock position
  • Quadrants

External Anatomy

  • Margins
  • Pectoralis muscle
  • Nipple/areola
    • Morgagni tubercles
    • Montgomery glands
    • Skin
    • Axillary tail
    • Inframammary fold

Internal Anatomy

  • Fascial layers
  • Retromammary space
  • Fibrous tissue
  • Glandular tissue
  • Adipose tissue
  • Cooper ligaments
  • Pectoralis muscle
  • Vascular structures
  • Lymphatic system

Cytology

  • Epithelial cells
  • Myoepithelial cells
  • Basement membrane

Pathology

  • Mammographic Appearance and Reporting Terminology (BI-RADS®)
    • Architectural distortion
    • Characteristics of masses and calcification
    • BI-RADS® categories
    • Benign Pathology
      • Risk factors for breast cancer
      • Incidence of breast cancer
      • Signs & symptoms
      • Documentation
      • Necessity of prior images
      • High Risk Pathology
      • Malignant Pathology

 

Session 3

6:30pm Eastern
5:30pm Central
4:30pm Mountain
3:30pm Pacific
What's my timezone?

Positioning & Procedures

Positioning Views

  • CC and MLO
  • ML and LM
  • Exaggerated CC
  • Cleavage
  • Axillary tail
  • Tangential
  • Rolled
  • Implants displaced
  • Nipple in profile
  • Anterior compression
  • Spot compression
  • Magnification

Special Patient Situations

  • Chest wall variations
  • Postsurgical-reduction, augmentation
  • Males
  • Kyphosis/Protruding abdomen
  • Lactating
  • Extremely large breasts
  • Extremely small breasts

Imaging Examinations

  • Mammography
    • Screening
    • diagnostic
    • Breast Ultrasound
    • Breast MRI
    • Sentinel node mapping

Interventional Procedures

  • Informed consent
  • Procedures/Associated imaging
  • Handling of biohazard materials
Session 4

6:30pm Eastern
5:30pm Central
4:30pm Mountain
3:30pm Pacific
What's my timezone?

Instrumentation & Quality Control

Purpose & Frequency

Design Characteristics of Mammography Systems

  • Tube
  • Grids
  • Compression Paddles
  • System Geometry

Mammograhic Technique

  • Kvp
  • MaS
  • AEC
  • Dose
  • X-ray Spectrum

Digital Acquisition/Display & Informatics

  • Acquisition workstation
  • Interpretation workstation
  • Hardcopy devices
  • HIS/RIS and mammo tracking
  • Newtworking (HL7/DICOM)
  • PACS
  • CAD
  • Digital workflow

Mammographer test

  • Phantom image
  • Compression thickness
  • Visual checklist
  • Acquisition/radiologist workstation monitors
  • Repeat analysis
  • Viewing conditions
  • Compression force
  • Manufacturer detector calibration

 

 

Audience

Who should attend?

  • Mammographers
  • Radiologic Technologists
  • Managers
  • Educators
  • Health care professionals involved in providing breast imaging services
  • Staff members of companies offering mammographic equipment and supplies

Program Faculty

Meet your presenter(s)

Cheryl Seastrand

Cheryl Seastrand

RT(R)(M)(BS)

Cheryl Seastrand has over 25 years of experience as a Breast Imaging Specialist. As a registered Mammographer and Breast Sonographer, Cheryl is committed to providing high quality development and delivery of education and training in Breast Imaging. She was on the ARRT Breast Sonography Practice Analysis Advisory Committee and has worked with additional professional affiliations on Mammography projects. Cheryl has a proven history of providing accurate, rational analysis and implementation of regulatory compliance and accreditation. Cheryl works extensively with breast imaging facilities nationally by providing competency assessment and recommended improvements to enhance breast imaging programs. 

Though Cheryl Seastrand is an ARRT committee member, by binding contract, Cheryl cannot reveal in whole or in part any ARRT's copyrighted questions or any other insider information about the ARRT's examinations or assessments. The ARRT does not review, evaluate, or endorse review courses, activities, materials, or products and this disclaimer should not be construed as an endorsement by the ARRT.

Miranda Melton

Miranda Melton

RT(R)(M)

Miranda became registered with the ARRT as a Radiologic Technologist in 1998 and specialized in Mammography in 1999. She spent the first 8 years working her way up from staff technologist to lead technologist before accepting a Clinic Manager Role with Diagnostic Imaging Centers, P.A. in Lee’s Summit, Missouri in 2006. After 10 years in that role, Miranda took a leap of faith in 2017 and began working as an Independent Mammography Positioning Specialist and Educator. Most of her time was spent teaching for Medical Technology Management Institute (MTMI) on the Initial Mammography Training team as well as traveling the US to provide hands-on positioning workshops. Miranda also worked part-time as Corporate Supervisor in the Mammography Department at University Health, Kansas City, Mo where she collaborated with the Lead Interpreting Physician to ensure all breast imaging protocols, workflows, quality control, and quality assurance issues/concerns were addressed and managed per MQSA/ACR guidelines. In February of 2023, Miranda accepted the position of Director of Women’s Imaging Education at MTMI. In this role, Miranda oversees and manages the Women’s Imaging portfolio of courses and events. Miranda is passionate about women’s health education and continues to provide hands-on positioning workshops as well as teaches several MTMI programs such as Initial Mammography Training, Essential Skills for Quality Mammography, Conquering MQSA and ACR and many more CEU webinars.   

Credits

Accredited training programs

ASRT Category A Credit Information

ASRT Category A

This program provides 4 hour(s) of Category A continuing education credit for radiologic technologists approved by ASRT and recognized by the ARRT and various licensure states.  Category A credit is also recognized for CE credit in Canada.  You must attend the entire program to receive your certificate of completion.  

A certificate of attendance, documenting 4 hours of credit will be provided for each individual upon completion of each 3.5 hour session of the webinar. Completion of all 4 sessions of this series will provide the 16 hours of structured education related to the content specifications outlined by the ARRT, required for certification and registration.Each session:Biennium CE Credits: 4Structured Education / CQR Credits: 4

Tuition

Convenient payment options available

AudiencePriceEarly PriceMember PriceMember Early Price
Technologist$99.00$95.00$89.00$85.00

Learn about membership

 ~ Tuition amount listed is per session. ~


Early Pricing Guidelines

Qualifying 'Early' registrations must be made at least 4 days in advance for the program.


Cancellation Policy

Webinars less than 8 hours of credit

Refunds, minus a $15 processing fee, will be granted for cancellations received at least 3 days prior to the program. Cancellations received within 3 days of the webinar will receive a credit toward a future MTMI program, minus the $15 processing fee. No refunds will be made after the webinar starts. MTMI reserves the right to cancel any scheduled program because of low advance registration or other reasons. MTMI’s liability is limited to a refund of any program tuition paid. WEBINAR ATTENDEES that cannot log in due to unsolvable technical issues beyond their control will be eligible for a full refund.